FORTUNE PERDANA LAKESIDE RESIDENCES @ METROPOLITAN PARK
Project Description
- GBI Rating
- Certificate No.
- GBI-RNC-0045
- Validity Date
- 08 Jun 2018 – 07 Jun 2021
- Building Category
- Residential New Construction (RNC)
- Location
- 1, JALAN METRO PERDANA, TAMAN USAHAWAN KEPONG, 52100 KUALA LUMPUR, Kuala Lumpur
- Local Authority
- DBKL - Dewan Bandaraya Kuala Lumpur
- Owner
- BH REALTY SDN BHD
Green Strategies 1. Energy Efficiency Ideal orientation of towers with the majority of windows facing north-south directions Apartment windows and sliding doors shaded with balconies as well as horizontal and vertical sun-shading devices Concrete roofs are well insulated to reduce heat gain Lobbies and corridors on typical floors are naturally ventilated and daylit 45 numbers of car parking bays have access to charging points for charging electric Energy efficient lighting provided for common area - LED fittings at lift lobbies, and corridors; and T5 fluorescent lights at carparks, plant rooms, and escape staircases All lifts in development are regenerative drive type where the regenerated power is used back in the building grid 2. Water Efficiency Rainwater harvesting resulting in reduction of common area potable water consumption of > 50% and no potable water consumption for landscape irrigation Water efficient fittings resulting in reduction of potable water consumption of > 50% Recycling of fire system test water for sprinkler and wet riser systems 3. Indoor Environmental Quality Low VOC paints used on all internal walls and ceilings 4. Reducing Heat Island Effect Extensive softscape covering 26% of total development area Edible landscaping in the form of herb or food species make up 17% of the total softscape area 5. Resource Conservation Building materials with high recycled content used where the recycled content cost constitutes 33% of the total project material cost Regional materials sourced from within 500km of the site used where the cost constitutes 35% of total project material cost Reusable aluminium system formwork used to reduce reliance on workers, improve workmanship and reduce waste Optimal use of concrete by structural elements being efficiently designed with reduction in sizes. The resultant Concrete Usage Index (CUI) is 0.41 m 3 /m2 which is much lower than the CUI of conventional reinforced concrete buildings. 6. Waste Reduction Recycling bins provided in convenient locations for residents to recycle their household waste QLASSIC score of 71% IBS score of 51%
Consultants
- Visit website
Fenestra Green Sdn BhdGBI Facilitator
- Arca3 Arkitek Sdn Bhd
Architect
- Pakatan Runding Yusoff Sdn Bhd
Civil & Structural Engineer
- C. J. Neo & Partners
Mechanical & Electrical Engineer
- QS Jurukos Sdn Bhd
Quantity Surveyor
- Visit websiteWDI Design Sdn Bhd
Landscape Architect