EKOCHERAS BLOCK A OFFICE
Project Description
- GBI Rating
- Certificate No.
- GBI-NRNC-0205(P)
- Validity Date
- 15 Sept 2017 – 14 Sept 2020
- Building Category
- Non-Residential New Construction (NRNC)
- Location
- NO. 693, BATU 5, JALAN CHERAS, 56000 KUALA LUMPUR, Kuala Lumpur
- Local Authority
- DBKL - Dewan Bandaraya Kuala Lumpur
- Owner
- EKOVEST CAPITAL SDN BHD
Green Strategies 1. Energy Efficiency Performance glazing with low-emissivity coating Energy monitoring system to monitor and analyse the monthly energy consumption data Maximum Demand Limiting program installed on the EMS to actively control the building elements in order to limit the instantaneous peak power consumed by the building as a whole, thus avoiding penalties imposed by the power companies. Photo-voltaic system with capacity of 200.4 kWp supplements electricity consumption of the air-conditioning chiller plant. This generation capacity is equivalent to 4% of the predicted energy consumption of the building. The air-conditioning system using chilled water fan coil units (FCU) allow a high degree of temperature control as there are many FCUs each serving a relatively small area of the floor which are independently adjustable by the office occupants. Lighting requirements in all tenancy agreements make it legally binding for all tenants to implement the following in their fit-outs: Limit interior lighting zones to no more than 100 m2 Average lighting illuminance level to comply with MS 1525 All luminaires to be high efficiency and longer life LED or T5 fluorescent light tubes with high frequency digital ballasts All installed lifts are regenerative drive lifts. A Commissioning Specialist engaged to provide commissioning advice, monitor and verify the commissioning of all building energy systems. 2. Water Conservation Water efficient fittings resulting in reduction of potable water consumption by more than 60% Rainwater harvesting resulting in reduction of potable water consumption of 59% for landscape irrigation Water sub-meters linked to the EMS help in automatically detecting any leakages or wastage of water Recycling of fire system test water for sprinkler and wet riser systems 3. Healthy Indoor Environment Good level of diffused lighting for significant portion of the office due to extensive high-performance glazing provided. 4. Resource conservation Efficient structural design with Concrete Usage Index of 0.34 m3/m2 reduces carbon footprint Reused building materials costing >7 % of total material cost Recycled content materials costing > 30% of total material cost Regional materials costing > 45% of total material cost Electric car charging points provided for 20 carpark bays Reserved parking for hybrid and electric cars as well as for carpool vehicles IBS score of 58 5. Reduction of heat island effect Softscape covering 40% of total development area 30% of softscape area consists of plant species that are considered herb or food. High albedo hardscape and roof finishes
Consultants
- Visit website
Fenestra Green Sdn BhdGBI Facilitator
- Visit website
Arkitek KDI Sdn BhdArchitect
- HNC Jurutera Perunding Sdn Bhd
Civil & Structural Engineer
- JPK & Associates
Mechanical & Electrical Engineer
- Yong Dan Mohamad Faiz Sdn Bhd
Quantity Surveyor
- Visit website
Praxcis Design Sdn BhdLandscape Architect